Sampling System for Liquids

Size Range:

DIN-EN: DN 15 – 100 / PN 10 – 40

ASME: NPS ½“ – 4“ / class 150 – 300

PT range:

-40 < T < 230°C, vacuum 10-8 mbar

Materials:

Standard body materials

  • Carbon Steel 1.0619, ASTM A216 WCB
  • Stainless Steel 1.4408, ASTM A351 CF8M
  • Stainless Steel 1.4308, ASTM A351 CF8
  • Unalloyed stainless steel casting (low Temp.) 1.1138, LCC/LCB/A352 Standard plug materials
  • Stainless Steel 1.4408, ASTM A351 CF8M
  • Stainless Steel 1.4308, ASTM A351 CF8 Special materials
  • Alloy
  • Monel
  • Nickel
  • Zirconium
  • Titan
  • Tantal
  • other materials on request

Design Features

closed system

cavity free

spilling eliminated and contamination free

specific defined representative sample quantity

pressure free sampling (positive overlap)

simple and fool safe operation

absolutely tight

utility model

fugitive emission resp. clean air act certified (TA – Luft 2002 approval) Directive 2014/68/EU

Bottle connection

PTFE-Adapter: for laboratory bottle with ISO-thread GL 32/45. Application: For less toxic resp. polluted

media.

Clamping Retainer: For fast and easy exchange of laboratory bottle, even for heated version.

Needle system: closed needle system for laboratory bottle with septum (Butyl and PTFE). Needle

System NH and NH-S with diverse internal diameter (2-6 mm). Application for high toxic resp. polluted

media for spillnig eliminated an contamination free sampling.